Hydraulic Cartridge Type Manual Operation Hand Pump

Model: HPC-9S series -111031
Place of Origin: Zhejiang,China (Mainland)
Power: Hydraulic
Standard or Nonstandard: Standard
Pressure: High Pressure
Structure: Shutoff
Material: Others
Temperature of Media: High Temperature
Media: Oil
Brand Name: Egmec
Product:: Cartridge Type Hydraulic Manual Hand Operated Pump
Operation pressure:: 207bar /3001.50PSI
Type:: Handed operated type
Flow rate:: 4.0-8.8 ml/Stroke
Allowable internal leakage:: 2drops per min. at 2000PSI
Working temperature:: -30~+120℃ or as customers indicated
Assembly type:: Cavity assembly
Medium:: Mineral based oil, such as 32#, 46#
Raw materials customized:: Available
Filtration:: ISO Standard 16/12

inquiry

basketAdd to Basket  Edit

Share |

Product Description

Payment & Shipping Terms Supply Capacity
Trade Term:FOBProduction Capacity:15000
Payment Terms:L/C, D/P, D/A, T/T, WUPacking:Standard packing for...
Min. Order:50 Set/SetsDelivery Date:Depending quantity
Means of Transport:Express, Ocean, Air, Land

Brief introduction:

    The HPA-9C series of cartridge type hydraulic manual hand pump is one kind of the hydraulic cartridge valves.

    How it works of cartridge type hydraulic manual hand pump: the piston is moving down and up to control the flow in or out. The volume between the piston and valve cavity is increase while the piston moves up, the oil is absorbed into the cavity through the check valve 1, on the contrary, the volume between the piston and valve cavity is decrease while the piston moves down, oil is pushed out of the cavity through the check valve 2, and the check valve1 is preventing leakage and keeping the pressure until the cavity is empty.

How to troubleshoot and repair the cartridge type hydraulic manual hand pump:
If you find out in the maintenance its following three causes of the malfunction, the following practices to modify the hand pumps:
1. Checking whether there is an internal leakage, the easiest way is to raise the handle, to check there is significant free to fall, if yes, please disassemble it to check if there are worn seals needed to be replaced.
2. Please check the abrasion of check valves, first cleaning check valves, confirmation wear of the spool should be timely replacement. Check valve installed, if still no change, then check the the spool wear, the clearance use limits generally 0.06mm badly worn should be replaced.
3. Measuring the pressure of the hand pump between the inlet and out port, if the pressure is low, it is necessary to make appropriate adjustments, plus the pressure is still not tune u , as evidenced by the hand pump by serious wear and needs to be replaced.

Hydraulic Cartridge Type Manual Operation Hand Pump

HPA-9C Series of Cartridge Type Hydraulic Manual Hand Pump Figures and Dimensions:

Hydraulic Cartridge Type Manual Operation Hand Pump
Hydraulic Cartridge Type Manual Operation Hand Pump

Category: Hydraulic Cartridge Hand Valves

Related Category: Hydraulic Cartridge Check Valves  Cartridge Type Check Valves  Hydraulic Cartridge Pressure Relief Valves  Hydraulic Cartridge Pressure Control Valves  Hydraulic Cartridge Flow Control Valves